2.19. Emergency closing of the panel of the hatch of a roof

At failure of the electric drive of the hatch of a roof execute the following.

 PERFORMANCE ORDER

1. Check serviceability of the fuse of the electric motor of the drive of the hatch of a roof, see the Section Safety locks. If the safety lock burned down, replace it with the serviceable safety lock calculated at the same or smaller size of rated current.
2. Try to close the roof hatch panel. If the new safety lock at once fuses or the electric motor still does not work, you can close the hatch manually.
3. Get a tool set from a luggage carrier.

4. By means of the screw-driver or a coin remove a round cap which is located on a ceiling and closes a turnkey nest.

5. Insert the cut end of a cranked key into a roof hatch drive coupling nest. Rotating the key handle clockwise, completely close the roof hatch.


6. Take out a key from a nest of the coupling and establish a cap into place.